Search


Information
ICMST-Tohoku 2018
Oct. 23 - 26, 2018
Sendai, Japan
ICMST-Shenzhen 2016
Nov 1 - 4, 2016
Shenzhen, China
(EXIT THIS PAGE)
ICMST-Kobe 2014
Nov 2(Sun) - 5(Wed), 2014
Kobe, Japan
Nuclear Regulation Authority Outline of the New Safety Standards for Light Water Reactors for Electric Power Generation
For Public Comment
Outline of New Safety Standard (Design Basis)
For Public Comment
New Safety Standards (SA) Outline (Draft)
For Public Comment
Outline of New Safety Standard(Earthquake and Tsunami)(DRAFT)
Issues
 

Vol.10 No.2(Aug)
Vol.10 No.1(May)
Vol.9 No.4(Feb)
Vol.9 No.3(Nov)

< Other Issues

 

Occasional Topics
OTjapan Measures for Tsunami Striking Nuclear Power Station in Japan
Special Article: The Great Tohoku Earthquake (1)
OTjapan The Tragedy of “To Be” Principle in the Japanese Nuclear Industry
EJAMOT_CN3_Figure1_The_outside_view_of_CEFR OTChinaPlanning and Consideration on SFR R&D Activities in China
< All Occasional Topics

Featured Articles
EJAM7-3NT72 A New Mechanical Condition-based Maintenance Technology Using Instrumented Indentation Technique
EJAM7-3NT73 Survey robots for Fukushima Daiichi Nuclear Power Plant

JSM
Contacts
(EJAM): ejam@jsm.or.jp
(JSM): secretariat@jsm.or.jp
HP: http://www.jsm.or.jp
(in English)

 

Vol.5 No.1 previous AA SP9 (59-60-61-62-63-64-65-66)-67-NT 56 -57

Academic Articles
Regular Paper Vol.5No.2 (2013) p.121 - p.127
 

Partial CT and Structural Analysis with 950 Kev/3.95 Mev X-Band Linac X-Ray Sources

 
Wenjing Wu 1,*, Haitao Zhu1, Ming Jin1, Katsuhiro Dobashi1, Takesi Fujiwara1, Mitsuru Uesaka1, Joichi Kusano2, Naoki Nakamura2. Eiji Tanabe2, Hideyuki Sunaga3,Yoshie Otake3
 
1The University of Tokyo, Department of Nuclear Engineering and Management, Room213, Nuclear Annex, 2-11-16 Yayoi, Bunkyo-ku, Tokyo, 113-0032, Japan
2Accuthera Inc., 2-7-6 Kurigi, Asaoku, Kawasaki, 215-0033, Japan
3Riken, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
 
Abstract
For the purpose of applying CT by X-band linac to NDE of bridges, NPPs and architectures, relative experiment and imaging reconstruction is studied. Three reconstruction algorithms of FBP, ART and SART are compared in consideration of partial projection situation because possible scanning is confined to smaller than 180° angle and a few translations during inspection. CT system with linacs under 4Mev for scanning will work on-site as Japanese law permitted. Moreover, 3D model can be built based on reconstructed images to evaluate load-bearing performance of bridges with VCAD system.
 
Keywords
CT, Linacs, X-ray, NDE
 
Full Paper: PDF EJAM Vol.5No.2 pp.121-127 "Partial CT and Structural Analysis with 950 Kev/3.95 Mev X-Band Linac X-Ray Sources "
















Article Information
Article history:
Received 9 November 2012
Accepted 10 June 2013