Search


Information
ICMST-Tohoku 2018
Oct. 23 - 26, 2018
Sendai, Japan
ICMST-Shenzhen 2016
Nov 1 - 4, 2016
Shenzhen, China
(EXIT THIS PAGE)
ICMST-Kobe 2014
Nov 2(Sun) - 5(Wed), 2014
Kobe, Japan
Nuclear Regulation Authority Outline of the New Safety Standards for Light Water Reactors for Electric Power Generation
For Public Comment
Outline of New Safety Standard (Design Basis)
For Public Comment
New Safety Standards (SA) Outline (Draft)
For Public Comment
Outline of New Safety Standard(Earthquake and Tsunami)(DRAFT)
Issues
 

Vol.10 No.2(Aug)
Vol.10 No.1(May)
Vol.9 No.4(Feb)
Vol.9 No.3(Nov)

< Other Issues

 

Occasional Topics
OTjapan Measures for Tsunami Striking Nuclear Power Station in Japan
Special Article: The Great Tohoku Earthquake (1)
OTjapan The Tragedy of “To Be” Principle in the Japanese Nuclear Industry
EJAMOT_CN3_Figure1_The_outside_view_of_CEFR OTChinaPlanning and Consideration on SFR R&D Activities in China
< All Occasional Topics

Featured Articles
EJAM7-3NT72 A New Mechanical Condition-based Maintenance Technology Using Instrumented Indentation Technique
EJAM7-3NT73 Survey robots for Fukushima Daiichi Nuclear Power Plant

JSM
Contacts
(EJAM): ejam@jsm.or.jp
(JSM): secretariat@jsm.or.jp
HP: http://www.jsm.or.jp
(in English)

 

Vol.6 No.4previous AA 82-SP13 (83-84-85-86)-NT67-68

Academic Articles
Regular Paper Vol.6 No.4 (2015) p.153 - p.164
 

Evaluation of Wall Thinning of the Steel Piping after Long Term Operation at Fugen Power Station

 
Ryosuke ANDO1, Teruyoshi ABE1, Takahisa NAKAMURA1
 

1 Japan Atomic Energy Agency, 65-20 Kizaki, Tsuruga , Fukui 914-8585, Japan

 
Abstract

Wall thinning of serviced carbon steel piping of the secondary cooling system after long term operation of Advanced Thermal prototype Reactor (ATR) Fugen power station has been investigated as a series of evaluation of validity and availability of utilization of serviced materials on research projects focused on aging management.
Reliability of wall thinning rates of the steel piping has been examined referring the previous inspection data.
Examinations also have been made on prediction of wall thinning rates, rationalization of management of pipe wall thinning and verification of countermeasures against wall thinning.

 

 
Keywords
serviced materials, steel piping, wall thinning, FAC, LDI, JSME code, ATR Fugen power station
 
Full Paper: PDF EJAM Vol.6No.4 pp.153-164 "Evaluation of Wall Thinning of the Steel Piping after Long Term Operation at Fugen Power Station"
Article Information
Article history:
Received 11 August 2014
Accepted 6 January 2015